Haag Streit Octopus 600 Perimeter
See the new pulse in perimetry
Novel perimeter technology for early diagnosis and standard white-on-white perimetry in one compact sized instrument.
Easy, straight forward operation with touch screen optimized and networkable EyeSuite® software that saves you and your patients time.
World innovation in perimetry – fast and reliable Pulsar test method for early glaucoma detection.
A perfect team: Early diagnosis and standard white-on-white perimetry in one device
The Octopus® 600 extends the successful HAAGSTREIT product range of visual field analysers combining the Pulsar method for early glaucoma detection and standard white-on-white perimetry for long term follow-up in one compact and standalone device. It is the first visual field analyser that performs standard white-on-white perimetry on an integrated flicker-free screen, using TFT and LED technology.
-Standalone or network integration
-Small footprint
-Maintenance-free LED background illumination
-No darkroom required
Novel perimeter technology for early diagnosis and standard white-on-white perimetry in one compact sized instrument.
Easy, straight forward operation with touch screen optimized and networkable EyeSuite® software that saves you and your patients time.
World innovation in perimetry – fast and reliable Pulsar test method for early glaucoma detection.
A perfect team: Early diagnosis and standard white-on-white perimetry in one device
The Octopus® 600 extends the successful HAAGSTREIT product range of visual field analysers combining the Pulsar method for early glaucoma detection and standard white-on-white perimetry for long term follow-up in one compact and standalone device. It is the first visual field analyser that performs standard white-on-white perimetry on an integrated flicker-free screen, using TFT and LED technology.
-Standalone or network integration
-Small footprint
-Maintenance-free LED background illumination
-No darkroom required
$
5,860.00
Haag Streit BM 900 Slit Lamp
Description
The Haag –Streit BM 900 has been the standard in modern slit lamp microscopy for almost 50 years – and still is! Over 100,000 professionals all over the world who own a BM 900 agree that it was the best investment they ever made for their practice. The BM 900 is the "classic" slit lamp for the eyecare professional concerned with both the anterior and posterior segments.
A convergent, stereoscopic microscope offering short observer to patient distances and "workhorse" 10 and 16 X magnifications (with standard 10 X eyepieces – optional eyepieces with other magnifications are available – see "Accessories"). PD and optical correction are both finely adjustable to give easy viewing with none of the eye fatigue so often associated with use of the slit lamp.
The Cross Slide Mechanism incorporated into all Haag –Streit slit lamps, has both vertical and horizontal movements controlled by our patented joystick. Perfection in design, materials and construction allow these movements to be made smoothly and effortlessly without any wrist or finger strain – and to continue so for the very long lifetime of this classic slit lamp.
The illumination system has the brightest (600,000 Lux) illumination available in a slit lamp providing a tilting, rotating slit up to 8 mm in length and width.
Tilting is extremely important to good posterior segment observation. All filter and slit controls are conveniently situated for ease of use and, as with the cross slide mechanism, have silky smooth, effortless movement. The slit mechanism, on of those "differences inside", is a masterpiece of engineering in itself, affording faultless precision in both shape and movement. Imaging A "through the eyepiece" digital adaptor for the BM 900 is available.
The Haag –Streit BM 900 has been the standard in modern slit lamp microscopy for almost 50 years – and still is! Over 100,000 professionals all over the world who own a BM 900 agree that it was the best investment they ever made for their practice. The BM 900 is the "classic" slit lamp for the eyecare professional concerned with both the anterior and posterior segments.
A convergent, stereoscopic microscope offering short observer to patient distances and "workhorse" 10 and 16 X magnifications (with standard 10 X eyepieces – optional eyepieces with other magnifications are available – see "Accessories"). PD and optical correction are both finely adjustable to give easy viewing with none of the eye fatigue so often associated with use of the slit lamp.
The Cross Slide Mechanism incorporated into all Haag –Streit slit lamps, has both vertical and horizontal movements controlled by our patented joystick. Perfection in design, materials and construction allow these movements to be made smoothly and effortlessly without any wrist or finger strain – and to continue so for the very long lifetime of this classic slit lamp.
The illumination system has the brightest (600,000 Lux) illumination available in a slit lamp providing a tilting, rotating slit up to 8 mm in length and width.
Tilting is extremely important to good posterior segment observation. All filter and slit controls are conveniently situated for ease of use and, as with the cross slide mechanism, have silky smooth, effortless movement. The slit mechanism, on of those "differences inside", is a masterpiece of engineering in itself, affording faultless precision in both shape and movement. Imaging A "through the eyepiece" digital adaptor for the BM 900 is available.
$
2,975.00
Haag Streit Lenstar LS900 Biometry
LENSTAR LS900 provides the user with a complete biometrical assessment of the patient’s eye in a single measurement procedure, including lens thickness, anterior
chamber depth (lens position) and retinal thickness.
- The all in one biometer, keratometer, pachymeter, pupillometer
and IOL calculator
Get up to nine measurements in one shot, including lens thickness.
- All measurements using laser optical technology
Align once, get all results.
- Measurements on the visual axis
Highly reproducible results on all parameters.
chamber depth (lens position) and retinal thickness.
- The all in one biometer, keratometer, pachymeter, pupillometer
and IOL calculator
Get up to nine measurements in one shot, including lens thickness.
- All measurements using laser optical technology
Align once, get all results.
- Measurements on the visual axis
Highly reproducible results on all parameters.
$
4,650.00
Haag Streit Octopus 300 Pro Perimeter
Description:
The Octopus 300 Pro is designed around the patented Interzeag direct projection system the Octopus 301 has defined the next level in the practice of perimetry. The 300 Pro includes TOP Strategy, Blue/Yellow Testing, LAN Interface board, Flicker Perimetry, CCFF Testing, Automatic Eye Tracking, all Printout formats, Custom Test Programs, EyeSuite Perimetry Software.Ideal for routine screening and threshold examinations.
The Octopus 300 Pro is designed around the patented Interzeag direct projection system the Octopus 301 has defined the next level in the practice of perimetry. The 300 Pro includes TOP Strategy, Blue/Yellow Testing, LAN Interface board, Flicker Perimetry, CCFF Testing, Automatic Eye Tracking, all Printout formats, Custom Test Programs, EyeSuite Perimetry Software.Ideal for routine screening and threshold examinations.
$
4,750.00
Haag Streit Octopus 300 Basic Perimeter
Description
The Octopus 300 Basic is designed around the patented Interzeag direct projection system the Octopus 301 has defined the next level in the practice of perimetry. The 300 Basic includes Includes TOP Strategy, LAN Interface Board, All Printout formats, CCFF Testing.Ideal for routine screening and threshold examinations.
The Octopus 300 Basic is designed around the patented Interzeag direct projection system the Octopus 301 has defined the next level in the practice of perimetry. The 300 Basic includes Includes TOP Strategy, LAN Interface Board, All Printout formats, CCFF Testing.Ideal for routine screening and threshold examinations.
$
3,950.00
Haag Streit Octopus 900 Perimeter
Description:
Six Methods – One Perimeter
100% Fixation Control – 100% of the Time.
Lightning-fast full threshold exams in fewer than 150 seconds
EyeSuite™ Software Analysis with networkable system and EMR Integration.
Goldmann Kinetic Perimetry in both manual and semi-automated modalities utilizing our full 90 Degree standard Goldmann bowl
Improved Patient Comfort and Greater Flexibility,
Six Methods – One Perimeter.
Static White/White – Track progression of disease
Blue/Yellow – Early detection with a clear media
Flicker – Early detection through a lens opacity
Low Vision – End stage disease
Goldmann Kinetic - Ideal for testing outside 30 degrees and for end-stage disease
Red/White – Special drug-induced maculopathies
100% Fixation Control – 100% of the Time.
100% Eye Fixation Control – if fixation is lost, no stimulus is presented.
Automatic Eye Tracking allows the instrument to track and adjust pupil automatically
Chin Rest Sensors – If patient pulls away, test pauses
Refractive Lens Control Sensors – Denotes proper range of refractive lenses
Automatic Pupil Measurement
Full Threshold in less than 150 seconds
Avoid errors caused by patient and retinal fatigue. ALL Octopus Perimeters come standard with our TOP (Tendency Oriented Perimetry) test strategy which provides a full 30 degree thresholds in less than 3 minutes per eye, whether you are running our 32 (30-2), G (Glaucoma Diagnostic) or M (Macula) thresholds.
EyeSuite™ Software Analysis.
Our EyeSuite™ Software allows for extensive and comprehensive analysis right at your fingertips. Unique physiological-based Polar and Cluster Graphs available.
Our clear 7-in-1 printout presents the most complete information needed for the assessment of your fields. Also, printout both eyes on one page by utilizing our 2-in-1 report and depicting your favorite graph.
Network compatibility allows results to be viewed on multiple viewing stations
Patient data is already saved to a pc and can be printed easily in an electronic format making EMR compatibility a snap.
Six Methods – One Perimeter
100% Fixation Control – 100% of the Time.
Lightning-fast full threshold exams in fewer than 150 seconds
EyeSuite™ Software Analysis with networkable system and EMR Integration.
Goldmann Kinetic Perimetry in both manual and semi-automated modalities utilizing our full 90 Degree standard Goldmann bowl
Improved Patient Comfort and Greater Flexibility,
Six Methods – One Perimeter.
Static White/White – Track progression of disease
Blue/Yellow – Early detection with a clear media
Flicker – Early detection through a lens opacity
Low Vision – End stage disease
Goldmann Kinetic - Ideal for testing outside 30 degrees and for end-stage disease
Red/White – Special drug-induced maculopathies
100% Fixation Control – 100% of the Time.
100% Eye Fixation Control – if fixation is lost, no stimulus is presented.
Automatic Eye Tracking allows the instrument to track and adjust pupil automatically
Chin Rest Sensors – If patient pulls away, test pauses
Refractive Lens Control Sensors – Denotes proper range of refractive lenses
Automatic Pupil Measurement
Full Threshold in less than 150 seconds
Avoid errors caused by patient and retinal fatigue. ALL Octopus Perimeters come standard with our TOP (Tendency Oriented Perimetry) test strategy which provides a full 30 degree thresholds in less than 3 minutes per eye, whether you are running our 32 (30-2), G (Glaucoma Diagnostic) or M (Macula) thresholds.
EyeSuite™ Software Analysis.
Our EyeSuite™ Software allows for extensive and comprehensive analysis right at your fingertips. Unique physiological-based Polar and Cluster Graphs available.
Our clear 7-in-1 printout presents the most complete information needed for the assessment of your fields. Also, printout both eyes on one page by utilizing our 2-in-1 report and depicting your favorite graph.
Network compatibility allows results to be viewed on multiple viewing stations
Patient data is already saved to a pc and can be printed easily in an electronic format making EMR compatibility a snap.
$
3,875.00
Haag Streit BA 904 Portable Slit Lamp
Portable Slit Lamp Haag-Streit BA 904 new!
For Use in Exam Room and Hospital Room
The BA 904® Slit Lamp has the unique ability to provide high quality examination either in the examination room, or as a hand-held device.
Features
- Haag-Streit optical system: 10x objectives; 16x as an option.
- Ergonomic design
- A Dioptic range of -8 to +8
- Interpupillary range of 53 to 65
- Safe and comfortable for patient
- Filters out hazardous radiation, which means less damage to the retina when used with a contact lens.Portable
- Fits into lightweight case
- Integrated rechargeable NICAD battery allows up to 45 minutes of continuous use per battery. Two batteries supplied
Technologically advanced
- Wider interpupillary dioptic range and field of view.
The following versions are available:
Set A:
Includes BA 904 portable slit lamp, head and chinrest stand, power centre, energy pack and large case.
Set C:
Includes BA 904 portable slit lamp, including power centre, energy pack and small case.
For Use in Exam Room and Hospital Room
The BA 904® Slit Lamp has the unique ability to provide high quality examination either in the examination room, or as a hand-held device.
Features
- Haag-Streit optical system: 10x objectives; 16x as an option.
- Ergonomic design
- A Dioptic range of -8 to +8
- Interpupillary range of 53 to 65
- Safe and comfortable for patient
- Filters out hazardous radiation, which means less damage to the retina when used with a contact lens.Portable
- Fits into lightweight case
- Integrated rechargeable NICAD battery allows up to 45 minutes of continuous use per battery. Two batteries supplied
Technologically advanced
- Wider interpupillary dioptic range and field of view.
The following versions are available:
Set A:
Includes BA 904 portable slit lamp, head and chinrest stand, power centre, energy pack and large case.
Set C:
Includes BA 904 portable slit lamp, including power centre, energy pack and small case.
$
2,025.00
Haag Streit BD 900 Slit Lamp
Description
The BD 900 Slit Lamp
The BD is optimized for the optician, optometrist, contact lens practitioners and ophthalmologists specializing in the anterior segment. It is also ideal for non-ophthalmologist within emergency rooms. Video- c-mount camera on the BD 900- may be fitted through a built-in video port. Standard magnification in 10 and 16 X times- through the flip of a lever placed just beneath the microscope.
Video Port A video port is included with the BD 900. The image is diverted to the camera by means of a small prism permanently placed within the microscope.
The video port on the BD 900 accepts a small C-Mount camera.
Yellow Filter For good contrast enhancement when using Fluoresceine, simply turn the filter positioned at the front of the microscope.
Instrument Base A smooth to operate instrument base with a continuously adjustable illumination control conveniently sited next to the joystick.
Illumination With a single support column the BD 900 allows optimal access to the patient. The halogen bulb gives up to 300,000 Lux illumination. The slit lamp adjusts from 0-14 mm. UV and IR filters are built-in and blue, red and grey filters can be introduced as needed.
The BD 900 Slit Lamp
The BD is optimized for the optician, optometrist, contact lens practitioners and ophthalmologists specializing in the anterior segment. It is also ideal for non-ophthalmologist within emergency rooms. Video- c-mount camera on the BD 900- may be fitted through a built-in video port. Standard magnification in 10 and 16 X times- through the flip of a lever placed just beneath the microscope.
Video Port A video port is included with the BD 900. The image is diverted to the camera by means of a small prism permanently placed within the microscope.
The video port on the BD 900 accepts a small C-Mount camera.
Yellow Filter For good contrast enhancement when using Fluoresceine, simply turn the filter positioned at the front of the microscope.
Instrument Base A smooth to operate instrument base with a continuously adjustable illumination control conveniently sited next to the joystick.
Illumination With a single support column the BD 900 allows optimal access to the patient. The halogen bulb gives up to 300,000 Lux illumination. The slit lamp adjusts from 0-14 mm. UV and IR filters are built-in and blue, red and grey filters can be introduced as needed.
$
2,490.00
Haag Streit BM 900 Slit Lamp
Description
The Haag –Streit BM 900 has been the standard in modern slit lamp microscopy for almost 50 years – and still is! Over 100,000 professionals all over the world who own a BM 900 agree that it was the best investment they ever made for their practice. The BM 900 is the "classic" slit lamp for the eyecare professional concerned with both the anterior and posterior segments.
A convergent, stereoscopic microscope offering short observer to patient distances and "workhorse" 10 and 16 X magnifications (with standard 10 X eyepieces – optional eyepieces with other magnifications are available – see "Accessories"). PD and optical correction are both finely adjustable to give easy viewing with none of the eye fatigue so often associated with use of the slit lamp.
The Cross Slide Mechanism incorporated into all Haag –Streit slit lamps, has both vertical and horizontal movements controlled by our patented joystick. Perfection in design, materials and construction allow these movements to be made smoothly and effortlessly without any wrist or finger strain – and to continue so for the very long lifetime of this classic slit lamp.
The illumination system has the brightest (600,000 Lux) illumination available in a slit lamp providing a tilting, rotating slit up to 8 mm in length and width.
Tilting is extremely important to good posterior segment observation. All filter and slit controls are conveniently situated for ease of use and, as with the cross slide mechanism, have silky smooth, effortless movement. The slit mechanism, on of those "differences inside", is a masterpiece of engineering in itself, affording faultless precision in both shape and movement. Imaging A "through the eyepiece" digital adaptor for the BM 900 is available.
The Haag –Streit BM 900 has been the standard in modern slit lamp microscopy for almost 50 years – and still is! Over 100,000 professionals all over the world who own a BM 900 agree that it was the best investment they ever made for their practice. The BM 900 is the "classic" slit lamp for the eyecare professional concerned with both the anterior and posterior segments.
A convergent, stereoscopic microscope offering short observer to patient distances and "workhorse" 10 and 16 X magnifications (with standard 10 X eyepieces – optional eyepieces with other magnifications are available – see "Accessories"). PD and optical correction are both finely adjustable to give easy viewing with none of the eye fatigue so often associated with use of the slit lamp.
The Cross Slide Mechanism incorporated into all Haag –Streit slit lamps, has both vertical and horizontal movements controlled by our patented joystick. Perfection in design, materials and construction allow these movements to be made smoothly and effortlessly without any wrist or finger strain – and to continue so for the very long lifetime of this classic slit lamp.
The illumination system has the brightest (600,000 Lux) illumination available in a slit lamp providing a tilting, rotating slit up to 8 mm in length and width.
Tilting is extremely important to good posterior segment observation. All filter and slit controls are conveniently situated for ease of use and, as with the cross slide mechanism, have silky smooth, effortless movement. The slit mechanism, on of those "differences inside", is a masterpiece of engineering in itself, affording faultless precision in both shape and movement. Imaging A "through the eyepiece" digital adaptor for the BM 900 is available.
$
2,975.00
Haag Streit BP 900 Digital Video / Photo Slit Lamp
Description
Three magnifications and imaging capabilities. Designed for routine practice, the BP 900 has a redesigned optical system. Two optical beam splitters, one for video, one for digital photography, allow the attachment of a consumer market digital cameras.
Magnification Changer Change between 10, 16 and 25 X magnification by means of a simple control on the side of the microscope.
Beam Splitter There are two optional beam splitters: one for video and one for digital photography. Each accepts commercially available cameras. 70% of the reflected light from the image is directed to the camera or video.
Joystick with Illumination Control A push button on the top of the joystick, unique to the BP 900, allows for the control of illumination levels.
Three magnifications and imaging capabilities. Designed for routine practice, the BP 900 has a redesigned optical system. Two optical beam splitters, one for video, one for digital photography, allow the attachment of a consumer market digital cameras.
Magnification Changer Change between 10, 16 and 25 X magnification by means of a simple control on the side of the microscope.
Beam Splitter There are two optional beam splitters: one for video and one for digital photography. Each accepts commercially available cameras. 70% of the reflected light from the image is directed to the camera or video.
Joystick with Illumination Control A push button on the top of the joystick, unique to the BP 900, allows for the control of illumination levels.
$
3,155.00
Haag Streit BQ 900 Slit Lamp
Description
The BQ 900, due to its excellent optics, versatility and ease of operation, has become the standard for those requiring advanced slit lamp microscopy. A universal, modular system, the BQ offers simultaneous video and still photography through either professional or consumer level cameras. A range of optional accessories include a teaching scope, inclined eyepiece and, for retinal specialist, the unique stereo variator. As with all Haag –Streit slit lamps, a Goldmann tonometer – the gold standard in IOP measurement – may be added to the system.
Beam Splitter The "key" to a wide range of accessories, the beam splitter diverts a portion of the light to secondary attachments such as the second observer tube, video, 35 mm or digital cameras. There are two ports which allow for simultaneous video / still photography or, alternatively, use of the second observer tube with either video or still cameras. The beam splitter may stay attached to the slit lamp as, by use of a simple lever, the full 100% light is sent back to the users eyepieces.
Inclined Eyepiece Adaptor This simple but effective device allows the eyepieces to be inclined upwards by 20 degrees from their traditional horizontal position, thereby reducing neck strain in allowing a more natural viewing position to the user.
Zoom –Objective The magnification can be continuously changed from 6 up to 40 X. Reference points are set at magnifications 10, 16 and 25X.
Second Observer Tube For teaching and assistants
Stereo Variator Uniquely with the BQ 900 an optional stereo variator reduces the 13 degree angle to 4.5 degrees. Thus enlarged binocular field of view is possible even with myopia or through small pupils. This also aids the observation, without additional lenses, of the peripheral fundus and vitreous.
The convergent stereo view offers a very large binocular field of view with high resolution and depth of focus. Eyepieces adjustable to all papillary distances allow for a fatigue free and relaxed examination, even during long examinations.
The BQ 900, due to its excellent optics, versatility and ease of operation, has become the standard for those requiring advanced slit lamp microscopy. A universal, modular system, the BQ offers simultaneous video and still photography through either professional or consumer level cameras. A range of optional accessories include a teaching scope, inclined eyepiece and, for retinal specialist, the unique stereo variator. As with all Haag –Streit slit lamps, a Goldmann tonometer – the gold standard in IOP measurement – may be added to the system.
Beam Splitter The "key" to a wide range of accessories, the beam splitter diverts a portion of the light to secondary attachments such as the second observer tube, video, 35 mm or digital cameras. There are two ports which allow for simultaneous video / still photography or, alternatively, use of the second observer tube with either video or still cameras. The beam splitter may stay attached to the slit lamp as, by use of a simple lever, the full 100% light is sent back to the users eyepieces.
Inclined Eyepiece Adaptor This simple but effective device allows the eyepieces to be inclined upwards by 20 degrees from their traditional horizontal position, thereby reducing neck strain in allowing a more natural viewing position to the user.
Zoom –Objective The magnification can be continuously changed from 6 up to 40 X. Reference points are set at magnifications 10, 16 and 25X.
Second Observer Tube For teaching and assistants
Stereo Variator Uniquely with the BQ 900 an optional stereo variator reduces the 13 degree angle to 4.5 degrees. Thus enlarged binocular field of view is possible even with myopia or through small pupils. This also aids the observation, without additional lenses, of the peripheral fundus and vitreous.
The convergent stereo view offers a very large binocular field of view with high resolution and depth of focus. Eyepieces adjustable to all papillary distances allow for a fatigue free and relaxed examination, even during long examinations.
$
3,625.00